SunSolve Power metering
Last updated: 26 November 2026. Published at sunsolve.com/legal/power/metering.
This page is the Metering Documentation for SunSolve Power under the SunSolve Subscription Terms. It defines the Usage Unit for SunSolve Power, the Ray, equal to one ray traced, and describes how each Simulation’s usage of the Fair Usage Allowance is calculated. It applies alongside the SunSolve Power Service Description at sunsolve.com/legal/power/service-description. Capitalised words have the meanings in the Subscription Terms. PVL may update this page under clause 6.8 of the Subscription Terms.
SunSolve Power usage is metered in Rays. One Ray is one ray traced. Your subscription includes an allowance of Rays for each 12 month period, and each simulation you run draws on it. As defined in clause 1.3 of the Subscription Terms, a million is 1,000,000 and a billion is 1,000 million, and the Service abbreviates them as M and B (for example, 2.5M rays or 93.66B rays). A typical simulation uses between 100,000 and 1 million Rays.
Definitions
| Term | Meaning |
|---|---|
| Ray | One ray traced by the ray tracer. This is the Usage Unit for SunSolve Power. |
| Run | One solution of the model. A single-solution simulation is one run. |
| Rays per run | The number of rays traced in each run, set on the Options tab (see Simulation options). |
| Usage | The number of Rays a simulation draws from the Fair Usage Allowance. |
Usage
Usage = runs × rays per run
Only a sweep or an optimisation contains more than one run:
- Sweep: the number of runs is shown on the Solver tab. It is the number of steps in the primary sweep multiplied by the number of steps in the secondary sweep, if there is one.
- Optimisation: the maximum number of runs is set on the Solver tab as the run limit. The usage shown before the simulation runs is an upper bound, shown as “up to”. The optimiser often stops earlier (see Termination conditions), so actual usage is usually lower. One exception: the first generation always runs in full, so if it contains more runs than the run limit, the estimate uses the first generation’s size instead.
The usage estimate and its breakdown are shown in the simulation bar before the simulation runs, so you can check any estimate against this page.
Examples
| Simulation | Runs | Rays per run | Usage |
|---|---|---|---|
| Single solution | 1 | 2 million | 2 million Rays |
| Sweep of 3 primary × 4 secondary steps | 12 | 500,000 | 6 million Rays |
| Optimisation with a run limit of 50 | up to 50 | 1 million | up to 50 million Rays |
See Simulation options for the ray tracer settings, and Ray count and stochastic error for how the number of rays affects results.